Date of Award

2021

Publisher

North Dakota State University

Document Type

Thesis

Degree Awarded

Master of Science (MS)

Program

Agricultural and Biosystems Engineering

Department

Agricultural and Biosystems Engineering

College

Agriculture, Food Systems and Natural Resources

Faculty Advisor

Flores, Paulo

Description

Advanced sprayer control systems aim to improve accuracy and reduce waste in spray application. The objective of this study was to determine an optimum prescription map cell size/resolution that is compatible with current technology. A prescription map with several cell sizes was created and tested in field conditions to evaluate the effect different cell size parameters have on spray accuracy. The outcomes show that the dependent variable cell width had the greatest effect on application accuracy (p-values < 0.05), followed by cell length, and that an optimum cell width of 1.5 m [4.92 ft], a length of 3.05 m [10 ft], and application speed of 10.3 km h-1 [6.4 mph] is recommended. To further refine this analysis, the testing should be expanded with the inclusion of a variety of manufacturers and equipment and a test prescription map with a truly randomized cell distribution to better reflect actual field conditions.

Rights

NDSU Policy 190.6.2

Rights Link

https://www.ndsu.edu/fileadmin/policy/190.pdf

Handle Identifier

https://hdl.handle.net/10365/32744

Share

COinS