Date of Award

2012

Publisher

North Dakota State University

Document Type

Thesis

Degree Awarded

Master of Science (MS)

Program

Mechanical Engineering

Department

Mechanical Engineering

College

Engineering

Faculty Advisor

Wang, Yechun

Description

Aortic stenosis is the most common valvular heart disease with a prevalence of 2% among individuals over 65 years and 4% over 80, in developed countries. Accurate valve assessment for intervention timing is critical. Using only routinely obtained clinical data, this research aims to present accurate recreations of in vivo transvalvular hemodynamics using computational fluid dynamics (CFD) and validate Gorlin formula and echocardiography (echo)/continuity techniques. The in vivo valve was compared to simplified and idealized geometries. Instantaneous anatomic orifice area (AOAmax) was underestimated by about 40% by Gorlin's formula and (dPmean). Time-averaged orifice area (EOAmean), by an echo/continuity, was about 40% smaller than the AOAmax. The Gorlin formula better assesses AOAmax using (dPmean eff). dPmean eff is required for Gorlin formula approximation of AOAmax and echo/continuity overestimates EOAmean with increasing error for lower flow rates. Correlations between EOA and AOA should only be made as instantaneous or only time-averaged comparisons.

Rights

NDSU Policy 190.6.2

Rights Link

https://www.ndsu.edu/fileadmin/policy/190.pdf

Handle Identifier

https://hdl.handle.net/10365/26625

Share

COinS